How to solve the wall-hung boiler e4 failure
Wall-hung boilers are common heating equipment in modern homes, but it is inevitable to encounter various fault codes during use, among which E4 fault is a common one. This article will give you a detailed analysis of the causes and solutions of wall-mounted boiler E4 failures, and provide hot topics and hot content on the entire network in the past 10 days for your reference.
1. The meaning of wall-hung boiler E4 failure

E4 fault usually indicates that the water pressure of the wall-mounted boiler is too high or the temperature sensor is abnormal. The following are common causes of E4 failures and corresponding solutions:
| Cause of failure | Solution |
|---|---|
| Water pressure is too high | Drain water through the drain valve at the bottom of the wall-hung boiler and reduce the water pressure to between 1-1.5bar. |
| Temperature sensor failure | Check whether the temperature sensor connection is loose and replace the sensor if necessary |
| System clogged | Clean the internal pipes of the wall-hung boiler, especially the heat exchanger part |
| Motherboard failure | Contact professional maintenance personnel to check or replace the motherboard |
2. Detailed troubleshooting steps for E4 faults
1.Check water pressure: Observe the pressure gauge of the wall-mounted boiler. The normal range should be between 1-1.5bar. If it exceeds 2bar, water needs to be drained to reduce the pressure.
2.Drainage operation: Turn off the power of the wall-mounted boiler, find the drain valve at the bottom, slowly open the drain, and observe the pressure gauge at the same time.
3.Check temperature sensor: If the water pressure is normal but E4 is still displayed, check whether the temperature sensor is firmly connected, and if necessary, use a multimeter to measure whether its resistance is normal.
4.System cleaning: If the above methods are ineffective, it may be that the system is clogged with scale and needs professional cleaning.
5.Contact after-sales: If the solution by yourself is ineffective, it is recommended to contact the brand’s after-sales service to avoid greater damage caused by self-disassembly.
3. Reference for hot topics on the entire network in the past 10 days
| hot topics | heat index |
|---|---|
| Winter Heating Equipment Maintenance Guide | 85% |
| Troubleshooting smart home devices | 78% |
| Impact of rising energy prices on households | 92% |
| DIY Home Repair Tips | 76% |
| Recommended environmentally friendly and energy-saving home appliances | 83% |
4. Routine maintenance suggestions to prevent E4 failure
1.Check water pressure regularly: It is recommended to check the water pressure of the wall-mounted boiler once a week and keep it within the standard range.
2.water quality treatment: Install a water softener or add protective agents regularly to prevent scale formation.
3.Professional maintenance: Before the heating season starts every year, ask professionals to do a comprehensive inspection and maintenance.
4.Pay attention to the ambient temperature: Avoid installing the wall-mounted boiler in an environment where the temperature is too low to prevent false alarms from the sensor.
5.Use original accessories: When replacing parts, be sure to use original accessories to ensure compatibility and safety.
5. Special instructions for E4 faults of common brands of wall-mounted boilers
| brand | Special instructions for E4 faults |
|---|---|
| power | It may indicate overheating protection and the operation of the water pump needs to be checked. |
| Bosch | Typically associated with temperature sensor failure |
| Ariston | It may be that the system pressure is too high or the water flow is not smooth |
| Macro | Commonly caused by water shortage or abnormal water pressure in the heating system |
6. Safety precautions
1. Be sure to turn off the power supply of the wall-mounted boiler before operation to prevent the risk of electric shock.
2. Pay attention to the water temperature when draining to avoid burns.
3. If you are not sure about the operation, it is recommended to contact professional maintenance personnel.
4. Do not disassemble gas-related parts by yourself, as this may cause safety hazards.
5. Regularly inspect gas pipelines and smoke exhaust systems to ensure safe operation.
Through the above detailed solutions and maintenance suggestions, I believe you can effectively deal with the wall-hung boiler E4 failure problem. If you encounter special circumstances, it is recommended to contact professional after-sales service in time to ensure the safety and normal use of the equipment.